Electrostatic transducers

500ES290

Electrostatic transceiver — A 50 kHz electrostatic transceiver with high sensitivity and a 17° typical -3 dB beam.

500ES290 electrostatic transceiver

Product image from catalog

Product overview

Electrostatic transceiver

Catalog listed

A 50 kHz electrostatic transceiver with high sensitivity and a 17° typical -3 dB beam.

Quote now
Published selection data
Center frequency50.0 ±1.0 kHz
Transmitting SPL116 dB min. at 300 V AC p-p / 200 V DC bias / 50 cm
Receiving sensitivity-65 dB re 1 V/µbar (-45 dB re 1 V/Pa)
Capacitance at 1 kHz600–700 pF
Suggested DC bias200 V
Suggested AC drive300 V p-p
Maximum combined voltage400 V
Beam angle (-6 dB)13° typical
Operating temperature0 to 60°C

Listed models and configurations

  • 500ES290-G gold-plated grid
  • 500ES290-A anodized aluminum grid
Catalog source: Specifications are transcribed from the 50-page Advantage TMS / Pro-Wave website catalog reviewed July 28, 2026. Values are typically stated at 25°C unless noted. Always request the current controlled datasheet, drawing, and revision before design release or purchase.

Selection guidance

Confirm performance in the complete system

Mounting, enclosure geometry, target material, temperature, airflow, electrical drive, gain, timing, and signal processing can materially change ultrasonic performance.

50Nominal frequency value or range in kHz unless shown otherwise
25°CTypical catalog reference condition
OEMApplication and integration support
RFQCurrent availability and controlled documents

Request 500ES290

Add this product and any alternatives to one RFQ, then include quantities, drawings, and delivery requirements.